Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Language
Year range
1.
Journal of Biomedical Engineering ; (6): 71-79, 2020.
Article in Chinese | WPRIM | ID: wpr-788894

ABSTRACT

In order to eliminate the influence of motion artifacts, high-frequency noise and baseline drift on photoplethysmographic (PPG), and to obtain the accurate value of heart rate in motion state, this paper proposed a de-noising method of PPG signal based on normalized least mean square (NLMS) adaptive filtering combining ensemble empirical mode decomposition(EEMD). Firstly, the PPG signal containing noise is passed through an adaptive filter with a 3-axis acceleration sensor as a reference signal to filter out motion artifacts. Secondly, the PPG signal is decomposed by EEMD to obtain a series of intrinsic modal function (IMF) according to the frequency from high to low. The threshold range of the signal is judged by the permutation entropy (PE) criterion, thereby filtering out the high frequency noise and the baseline drift. The experimental results show that the Pearson correlation coefficient between the calculated heart rate of PPG signal and the standard heart rate based on electrocardiogram (ECG) signal is 0.731 and the average absolute error percentage is 6.10% under different motion states, which indicates that the method can accurately calculate the heart rate in moving state and is beneficial to the physiological monitoring under the state of human motion.

2.
Chinese Journal of Industrial Hygiene and Occupational Diseases ; (12): 459-462, 2017.
Article in Chinese | WPRIM | ID: wpr-808787

ABSTRACT

Objective@#To investigate the influence of extremely low-frequency magnetic field on periodical expression of cryptochrome (Cry) gene in mouse embryonic fibroblast NIH3T3 cells.@*Methods@#The NIH3T3 cells were divided into magnetic field group and sham-exposure group. The NIH3T3 cells in the magnetic field group were stimulated by horse serum and then exposed to an extremely low-frequency magnetic field (50 Hz and 0.3 mT) for 48 hours, and those in the sham-exposure group were also stimulated by horse serum and then exposed to a coil for 48 hours. The NIH3T3 cells were collected, total RNA was extracted, and cDNA was obtained via reverse transcription. Real-time fluorescent quantitative RT-PCR was used to measure the changes in transcription cycles of Cry and Period genes in both groups.@*Results@#There was no significant difference in the proliferation rate at 0, 12, 24, and 48 hours of exposure between the two groups (P>0.05) . Both sham-exposure group and magnetic field group showed a rhythmic change in the expression of Cry gene, and compared with the sham-exposure group, the magnetic field group had a significantly shortened circadian rhythm of Cry gene in NIH3T3 cells (t=2.57, P<0.05) . Both groups had rhythmic and periodical expression of Period gene and there was no significant difference between the two groups (t=0.70, P>0.05) .@*Conclusion@#Extremely low-frequency magnetic field can significantly shorten the circadian rhythm of Cry gene in mouse embryonic fibroblasts, while there is no significant change in the circadian rhythm of Period gene.

3.
Chinese Medical Equipment Journal ; (6): 32-34,44, 2017.
Article in Chinese | WPRIM | ID: wpr-606357

ABSTRACT

Objective To develop a portable pressure detector to facilitate the battlefield self and buddy aids training for dressing,hemostasis and fixation.Methods The changes of pressure were converted into the ones of electric current with the pneumatic cuff,catheter and membrane pressure sensor,and then transmitted to the panel display by Bluetooth.The efficacy for the training was determined based on the acquired data.Results The detector implemented quantifying of the pressures during dressing,hemostasis and fixation,and non-medical staff obtained the results of battlefield treatment training easily to execute rapid assessment of battlefield self and buddy aids training.Conclusion The device gains advantages in visualized data,portability,easy operation and accurate measurement,and contributes to battlefield self and buddy aids training.

SELECTION OF CITATIONS
SEARCH DETAIL